To open the **Off... Window**, press and hold ![ma](/img/dot2/ma-36da5c.png) + Off at the console. The Off... Window opens at screen 1.

![](/img/dot2/dot2_viewsandwindows_off01_1-1-3-c43be7.png)_Figure 1: Off Window_

To apply a off function, tap at the button or press the encoder.

In the Off... Window are four buttons available:

**Everything off:**\
Turns all executor off, resets all special masters and clears the programmer.

**Turn all Executors off**:\
Turns off all running cues and chasers.

**Reset all Special Masters:**\
Turns off the program time master and executor master.\
Resets the master speed to 60 BPM.\
Resets the master rate to 1:1.\
Resets the group master to 100%.

**Clear Programmer:**\
Deselect the selected fixtures in the fixtures view.\
Deletes all values in the programmer and set them back to the default values or to values from executors.

**Hint:**\
Double-check the programmer values in the [fixtures sheet view](/dot2/key_viewitem_fixture/).

**Hint:**\
Clear programmer is the same function as press the [Clear Key](/dot2/key_key_clear/) twice.

## Encoder Bar Functions

![](/img/dot2/dot2_viewsandwindows_off02_1-0-aca2db.png)_Figure 2: Encoder Bar Off... Window_

**Select:**\
To select one of the three off buttons, turn the encoder left or right. The selected is displayed in a brighter gray.\